The buffer tanks of series PR2 of the company SUNSYSTEM used for improving the performance and efficiency of heating, through the production and storage of hot water, which is used in the central space heating system. These specific buffer tanks allow the use of up to 3 external heat sources and optional kit for electric heating with nominal power 3kW, 4.5kW, 6kW or 7.5kW.
Product Features
- Range of volumes of 300-3000 liters
- Upright storage tank made of steel S235JR
- Primer coated on the outside
- CFC free soft PU-foam insulation with thickness of 100 mm
- PVC coating in RAL 9006 or other colors on demand
- All threads are internal
- Option for installing a heating element as back-up source of heat
- Compressive strength 3 bar
Energy Efficiency Directive 2010/30 /EU,
Regulation 812/2013:
Class E - capacity from 300 to 500 Liters;
Class Е - capacity from 800 to 1000 Liters;
1. Aesthetic PVC jacket with color RAL 9006
2. Primer coated outer surface
3. Removable insulation
4. Water tank of low-carbon steel
5. Lower coil S1
6. Upper coil S2
Characteristics | |
Weight (kg) | 456.0000 |
Country of Manufacture | Bulgaria |
Dimension Height (mm) | 2250 |
Warranty | 2 Years |
Thermometer | Optional |
Water capacity/content (L) | 2000 |
Lower coil S1 capacity (L) | 24.6 |
Installation | Free standing |
Heat exchanger coil | Two heat exchanger coils |
Height without insulation (mm) | 2200 |
Diameter (mm) | 1350 |
Diameter without insulation (mm) | 1150 |
Minimum vertical clearance (mm) | 2260 |
Insulation weight (kg) | 26.5 |
Lower coil S1 heat exchanging surface (m²) | 4.0 |
Maximum buffer operating temperature (°C) | 95 |
Recommended size of the boiler connected to the buffer (kW) | 36 - 67 |
Sensor sleeve A (mm) | G 1/2'' / 920 |
Electric heating element B (mm) | G 1 1/2'' / 1170 |
Sensor sleeve C (mm) | G 1/2'' / 1690 |
Air vent sleeve D (mm) | G 1 1/2'' / 2200 |
Boiler heat carrier E (mm) | G 1 1/2'' / 1820 |
Sensor sleeve G (mm) | G 1/2'' / 1590 |
Boiler heat carrier H (mm) | G 1 1/2'' / 1420 |
Boiler heat carrier J (mm) | G 1 1/2'' / 1170 |
Heat carrier inlet L (mm) | G 1'' / 980 |
Boiler heat carrier M (mm) | G 1 1/2'' / 735 |
Sensor sleeve N (mm) | G 1/2'' / 500 |
Maximum coil operating temperature (°C) | 110 |